A method for analysis of marker persistent organic pollutants in low-volume plasma and serum samples using 96-well plate solid phase extraction

Logo poskytovatele

Varování

Publikace nespadá pod Fakultu sociálních studií, ale pod Přírodovědeckou fakultu. Oficiální stránka publikace je na webu muni.cz.
Autoři

STUBLESKI Jordan KUKUČKA Petr SALIHOVIC Samira LIND P. Monica LIND Lars KARRMAN Anna

Rok publikování 2018
Druh Článek v odborném periodiku
Časopis / Zdroj Journal of Chromatography A
Fakulta / Pracoviště MU

Přírodovědecká fakulta

Citace
www https://www.sciencedirect.com/science/article/pii/S002196731830253X?via%3Dihub
Doi http://dx.doi.org/10.1016/j.chroma.2018.02.057
Klíčová slova High-throughput SPE; Persistent organic pollutants; GC-HRMS; APCI-MS/MS
Popis The objective of this study was to develop and validate a 96-well plate solid phase extraction method for analysis of 23 lipophilic persistent organic pollutants (POPs) in low-volume plasma and serum samples which is applicable for biomonitoring and epidemiological studies. The analysis of selected markers for internal exposure: 16 polychlorinated biphenyls (PCBs), 5 organochlorine pesticides (OCPs), octachlorinated dibenzo-p-dioxin (OCDD), and polybrominated diphenylether 47 (BDE 47) was evaluated by comparing two SPE sorbents and GC-HRMS or GC-MS/MS detection. The final method extracted 23 POPs from 150 mu L of serum and plasma using a 96-well extraction plate containing 60 mg Oasis HLB sorbent per well prior to GC-HRMS magnetic sector analysis. The extraction method was applied to 40 plasma samples collected for an epidemiological study. The recovery of selected POPs ranged from 31% to 63% (n = 48), and detection limits ranged from 2.2 to 45 pg/mL for PCBs, 4.2 to 167 pg/mL for OCPs, 7.8 pg/mL for OCDD and 6.1 pg/mL for BDE 47. This method showed good precision with relative standard deviations of selected POP concentrations in quality control samples (n = 48) ranging from 11% to 25%. The trueness was determined with standard reference material serum (n = 48) and the deviation from certified values ranged from 1 to 27%. Of the 23 POPs analyzed, 18 were detected in 43% to 100% of plasma samples collected for the epidemiological study. The method showed good robustness with low inter-well plate variation (11-31%) determined by twelve 96-well plate extractions, and can extract 96 samples, including quality controls and procedural blanks in 2-3 days. Comparison with GC-MS/MS analysis showed that similar concentrations (within 0.5% to 30%) of most POPs could be obtained with GC-APCI-MS/MS. Larger deviations were observed for PCB 194 (60%) and trans-nonachlor (43%). The developed method produces accurate concentrations of low-level marker POPs in plasma and serum, providing a suitable high-throughput sample preparation procedure for biomonitoring and epidemiological studies involving large sample size and limited sample volume. GC-HRMS was chosen over GC-MS/MS, however the latter showed promising results, and could be used as an alternative to GC-HRMS analysis for most POPs.
Související projekty:

Používáte starou verzi internetového prohlížeče. Doporučujeme aktualizovat Váš prohlížeč na nejnovější verzi.