Quantifying argon and metal ion fluxes in HiPIMS using a biasable QCM

Varování

Publikace nespadá pod Fakultu sociálních studií, ale pod Přírodovědeckou fakultu. Oficiální stránka publikace je na webu muni.cz.
Autoři

ONDRYÁŠ Martin KLEIN Peter HNILICA Jaroslav VAŠINA Petr

Rok publikování 2025
Druh Článek v odborném periodiku
Časopis / Zdroj Surface and Coatings Technology
Fakulta / Pracoviště MU

Přírodovědecká fakulta

Citace
www https://doi.org/10.1016/j.surfcoat.2025.132847
Doi https://doi.org/10.1016/j.surfcoat.2025.132847
Klíčová slova Ar ion flux; HiPIMS; Ionisation measurement; IPVD; Magnetron sputtering; QCM
Popis This paper presents measurements of particle fluxes at the substrate during a HiPIMS discharge using a novel biasable quartz crystal microbalance system, enabling detection of Ti neutrals, Ti ions, and, for the first time, Ar ions. Two target geometries were compared at equal power density and peak current density, and two different power supplies were tested under nominally identical conditions to assess the role of generator design. The study shows that particle fluxes are strongly affected by target geometry, pressure, and generator type. The rectangular target produced higher and more variable fluxes than the circular one, while increasing pressure consistently reduced them. Differences between generators mainly influenced the balance between Ti neutrals and ions, whereas Ar ion fluxes remained similar. Overall, Ar ion fluxes were consistently dominant, exceeding Ti ion fluxes by about an order of magnitude.
Související projekty: