Bioassay battery interlaboratory investigation of emerging contaminants in spiked water extracts - Towards the implementation of bioanalytical monitoring tools in water quality assessment and monitoring

Logo poskytovatele

Varování

Publikace nespadá pod Fakultu sociálních studií, ale pod Přírodovědeckou fakultu. Oficiální stránka publikace je na webu muni.cz.
Autoři

DI PAOLO Carolina OTTERMANNS Richard KEITER Steffen AIT-AISSA Selim BLUHM Kerstin BRACK Werner BREITHOLTZ Magnus BUCHINGER Sebastian CARERE Mario CHALON Carole COUSIN Xavier DULIO Valeria ESCHER Beate I. HAMERS Timo HILSCHEROVÁ Klára JARQUE ORTIZ Sergio JONÁŠ Adam MAILLOT-MARECHAL Emmanuelle MARNEFFE Yves NGUYEN Mai Thao PANDARD Pascal SCHIFFERLI Andrea SCHULZE Tobias SEIDENSTICKER Sven SEILER Thomas-Benjamin TANG Janet VAN DER OOST Ron VERMEIRSSEN Etienne ZOUNKOVÁ Radka ZWART Nick HOLLERT Henner

Rok publikování 2016
Druh Článek v odborném periodiku
Časopis / Zdroj Water Research
Fakulta / Pracoviště MU

Přírodovědecká fakulta

Citace
www http://www.sciencedirect.com/science/article/pii/S0043135416306182
Doi http://dx.doi.org/10.1016/j.watres.2016.08.018
Obor Vliv životního prostředí na zdraví
Klíčová slova Triclosan; Acridine; 17 alpha-ethinylestradiol; 3-Nitrobenzanthrone; Organism-level toxicity; Mechanism-specific toxicity
Popis Bioassays are particularly useful tools to link the chemical and ecological assessments in water quality monitoring. Different methods cover a broad range of toxicity mechanisms in diverse organisms, and account for risks posed by non-target compounds and mixtures. There is a need to address bioassay suitability to evaluate water samples containing emerging pollutants, which are a current priority in water quality monitoring. The presented interlaboratory study (ILS) verified whether a battery of miniaturized bioassays, conducted in 11 different laboratories following their own protocols, would produce comparable results when applied to evaluate blinded samples consisting of a pristine water extract spiked with four emerging pollutants as single chemicals or mixtures, i.e. triclosan, acridine, 17 alpha-ethinylestradiol (EE2) and 3-nitrobenzanthrone (3-NBA). Assays evaluated effects on aquatic organisms from three different trophic levels and mechanism-specific effects using in vitro estrogenicity and mutagenicity assays. The test battery presented complementary sensitivity and specificity to evaluate the different blinded water extract spikes. Estrogenicity and mutagenicity assays identified with high precision the respective mechanism-specific effects of spikes even when non-specific toxicity occurred in mixture. Differences in experimental protocols, model organisms, and data analysis can be sources of variation, indicating that respective harmonized standard procedures should be followed when implementing bioassays in water monitoring. Together with other ongoing activities for the validation of a basic bioassay battery, the present study is an important step towards the implementation of bioanalytical monitoring tools in water quality assessment and monitoring.
Související projekty:

Používáte starou verzi internetového prohlížeče. Doporučujeme aktualizovat Váš prohlížeč na nejnovější verzi.